• Name: PL18 1000W~6000W
  • 产品编号: E007
  • Input voltage: 95-126VAC OR 194-253VAC±4%
  • Output voltage: 110/120/130VAC OR 220/230/240VAC±10%rms
  • Optional DC voltage: 12v/24v/48v
  • AC charge current: 20A/35A/50A/75A/90A(According to the inverter model)
  • Solar charge controller: External charge controller
  • Waveform: Pure Sine Wave
  • Transfer time: <15ms
  • Inverter type: Low frequency solar inverter
  • Views : 572

  • LCD digital display show voltage, load and battery information in real time.
  • Peak power is three times of rated power.
  • Can work with inductive load such as air conditioner, motor door and so on.
  • Pure sine wave output, available for sensitive load.
  • 4-step progressive charging, 7 battery type selector.
  • Fast and powerful charger with 35A and 70A/90A.
  • Accept generator’s energy output.
  • High power factor 0.9, low power consumption.
  • Automatically transfer between battery and line modes.
  • Microprocessor control guarantees high reliability.
  • Remote control function.
  • Protection against: Over load, over temperature, over charging, low battery

 

Model No. PL18-1000 PL18-1500 PL18-2000 PL18-3000 PL18-4000 PL18-5000 PL18-6000
Nominal Power 1000W 1500W 2000W 3000W 4000W 5000W 6000W
AC Input
Phase & waveform Single phase & Pure Sine Wave
Voltage 110/120/130VAC OR 220/230/240VAC
Acceptable Voltage 95-126VAC   OR    194-253VAC±4%
Line Low Transfer 85VAC±4% OR 184VAC ±4%
Line Low Return 95VAC±4% OR 194VAC ±4%
Line high Transfer 136VAC±4%/263VAC±4%
Line high Return 126VAC±4%/253VAC±4%
Frequency 50Hz:41-54Hz or 60Hz:51-64Hz (auto sensing)
Output
Phase & waveform Single phase & Pure Sine Wave (bypass mode sync to input)
Voltage 110/120/130VAC   OR   220/230/240VAC±10%rms 
(bypass mode sync to input)
Frequency 50Hz/60Hz±0.3Hz (bypass mode sync to input)
Peak Power 3 times of rating power
Short Circuit Protection Yes, shutdown after 10ms
Power Factor 0.9-1.0
DC Input
Battery Voltage 12v/24v 12v/24v/48v 24v/48v
Minimum Start Voltage 10V for 12V, 20V for 24V, 40V for 48V
Low Battery Alarm 10.5V for 12V, 21V for 24V, 42V for 48V
Low Battery Transfer 10V for 12V, 20V for 24V, 40V for 48V
High Voltage Alarm 16V for 12V, 32V for 24V, 64V for 48V
Max Charging Current 20A/35A/50A/75A/90A(According to the inverter model)
Transfer Efficiency
Line Mode >96%
Battery Mode >85%
System Parameter
power saver load  25 Watts(Enabled on "P/S auto"setting of Remote control)
Audible Alarm Sounding when the heat sink's tem is over 105and shutdown after 30 seconds.
Over load Protections

110%load150%beeps 0.5s every 1s,and fault after 60s. 

 Load150%beeps 0.5s every 1s,and Fault after 20s

Protections low battery,over charging,over temp,over load
Communications RS-232/USB/SNMP(custom-made)
Environmental
Operating Environment 0-40,0-90%RH(non-condensing)
Audible Noise <60dB
Physical
Net Weight(KG) 15 17.5 19.5 25 35.5 39 47.5
Dimension, L X W X H(mm) 470*223*185 650*223*185
 