• name: GH33 30kva~80kva (384VDC)
  • 产品编号: B007
  • Input voltage range: 3 * 400 VAC (3 Ph+N)
  • Output voltage range: 3 * 360/380/400/415 VAC (3 Ph+N) ± 1%
  • power factor: ≧ 0.99 @ 100% Load
  • Power efficiency: >92%
  • waveform: pure sine wave
  • Transfer time: 0ms
  • Views : 403

  • True double-conversion
  • DSP technology guarantees high reliability
  • Output power factor 0.9
  • Active power factor correction in all phases
  • 50Hz/60Hz frequency converter mode
  • ECO mode operation for energy saving
  • Emergency power off function (EPO)
  • Optional paralle operation
  • Smart battery charger design to optimize battery performance
  • Maintenance bypass available
  • Adjustable battery design
  • Adjustable charging current only available for 100K and up models
  • Optional 10" touch colored LCD only available for 100K and up models
Model GH 3/3 30K (L) GH 3/3 40K (L) GH 3/3 60KL GH 3/3 80KL
PHASE 3-phase in/3-phase out
CAPACITY 30KVA/27KW 40KVA/36KW 60KVA/54KW 80KVA/72KW
INPUT
Nominal Voltage 3 x 400 VAC (3 Ph+N)
Voltage Range 190-520 VAC (3-Phase) @ 50% Load; 305-478 VAC (3-Phase) @ 100% Load
Frequency Range 46~54 Hz or 56~64 Hz
Power Factor  0.99 @ 100% Load
OUTPUT
Output Voltage 3 x 360*/380/400/415 VAC (3 Ph+N)
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Synchronized Range) 46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion  2 % THD (Linear Load);  5 % THD (Non-linear Load)
Transfer Time AC Mode to Batt. Mode Zero
Inverter to Bypass Zero
Waveform (Batt. Mode) Pure Sinewave
Overload AC Mode 100-110% for 10 min, 110-130% for 1 min, >130% for 1 second
Battery Mode 100-110% for 30 seconds, 110-130% for 10 seconds, >130% for 1 second
Parallel Capacity up to 3 units in parellel
EFFICIENCY
AC Mode 95.00%
ECO Mode 98.00%
Battery Mode 92.00% 92.00% 92.00% 92.00%
BATTERY
Standard Model Battery Type 12 V / 7 Ah 12 V / 9 Ah N/A
Numbers (16+16) pcs x 2 strings (16+16) pcs x 2 strings
Typical Recharge Time 9 hours recover to 90% capacity
Charging Current (Max.) 2A
Charging Voltage ± 218 VDC
Long-run Model Battery Type Depending on the capacity of external batteries
Numbers 32~40 pcs (Adjustable)
Charging Current (Max.) 4A 4A
Charging Voltage ± 13.65V x N (N=16~20)
INDICATORS
LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
PHYSICAL
Standard Model Dimension, DxWxH (mm) 815 x 300 x 1000 N/A
Net Weight (kgs) 205 230
Long-run Model Dimension, DxWxH (mm) 815 x 300 x1000 790 x 360 x 1010
Net Weight (kgs) 60 61 108 113
ENVIRONMENT13
Operation Temperature 0-40 °C
Operation Humidity < 95% and non-condensing
Noise Level Less than 75dB @1Meter
MANAGEMENT
Smart RS-232/USB Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser
 