SKGH33-10-200KS
![]()
High performance index 1. The advanced intelligent control technology of silicon controlled rectifier can realize the input power factor of 0.95 and input harmonic current less than 5% when the harmonic filter is connected; 2. Adopt IGBT inverter control technology, output power factor PF=0.9, output voltage and current performance is more excellent. Online three-input three-output double conversion structure, supporting 380/400/415V, 50/60Hz power grid system; 3. The wide input voltage is 380Vac (286-475Vac) and the frequency range is 50/60 Hz±5%, and the grid adaptability is strong; 4. The output power factor is as high as 0.9, which is 12.5% stronger than traditional UPS load capacity; 5. It can be adapted to various generator equipment; 6. The efficiency of the whole machine is as high as 90%; in ECO operation mode, its energy conversion efficiency is as high as 98%, and the energy saving effect is very significant; 7. Strong load adaptability and output overload and short-circuit capacity, peak current protection technology, so that overload capacity: 110-125% of the load can run normally for 10 minutes, 125-150% of the load can run normally for 1 minute; 8. Intelligent battery management system design, with constant charge, floating charge and equalization, as well as temperature compensation; flexible battery configuration, the number of battery cells per group can be set on the operation panel to 32/31/30/29/28 . 9. Intelligent fault diagnosis, abundant fault records, large-capacity fault storage space; 10. Friendly man-machine interface, color touch screen combined with keyboard, convenient operation. Safe, stable and easy to maintain 11. Adopt the latest digital signal controller (DSP) to realize 100% digital control and operation of UPS power system, and combine multiple single-chip microprocessors for system redundancy control; 12. Adopt dual mains input or single mains input, so that the user's power supply is more securely guaranteed; 13. Diagnosis of phase loss and wrong phase, prompt warning; 14. Allow 100% three-phase unbalanced load; 15. Adopt frontal maintenance design; MTBF up to 300,000 hours mean time between failures and lower mean time to repair; 16. More than 90% of the components in the system design adopt international brands, and the equipment has undergone 24-hour aging and related verification tests before leaving the factory to ensure the high reliability of the system. Mains input
Battery parameters
Inverter output
Static bypass
Power saving mode (default off)
Environmental parameters
Structural parameters
|