400-800-2788
|
SKMK33-30-200KS
![]()
High performance index 1. The SKMK series power system is a modular redundant parallel system design, composed of 1 to 10 UPS power modules with a rated capacity of 20KVA, which can be expanded by online hot swapping. Users can expand the UPS system by increasing the number of modules when the load capacity increases. The scalability is strong, which greatly reduces the user's operating capital investment; 2. The SKMK series power supply system adopts advanced power phase and capacity multi-standard technology, and can choose "three-phase input three-phase output" and "three-phase input single-phase output" according to the power input, and maintain the total power constant; 3. The modules in the SKMK series power system are relatively independently controlled, and the system will not be affected by any module failure. The redundancy function can be fully utilized to fully guarantee the normal operation of the equipment and achieve the maximum failure redundancy; 4. The SKMK series power system utilizes advanced intelligent fault offline hot swap technology. The power module of a single fault can be put into or removed from the parallel unit at will without power outage operation, and realize and contact the online maintenance of the system; 5. SKMK series power system parallel technology has super parallel capability, which improves the high reliability of UPS power system to a new level. Its mean time between failures (MTBF) is 1.5 times that of traditional UPS systems. The major failure value (MTBCF) is three times that of the traditional UPS system, and the mean time to repair (MTTR) is reduced to only 5 minutes; 6. The two-way information monitoring and self-test functions of the SKMK series power system can fully understand the operation of the power system; 7. SKMK series power system adopts advanced PFC circuit design, input total harmonic distortion (THDI) reaches 5%, unit input power factor PF=0.99, under linear load conditions, output total harmonic distortion (THD) is less than 2% . Greatly reduce grid pollution, effectively reduce grid load and power loss, and the efficiency of the whole machine is as high as 95%, which greatly saves energy. Safe, stable and easy to maintain 1. The use of redundant module technology improves the safety and stability of the system; 2. The application of online hot swap technology can greatly reduce the repair time of system failures; 3. With modular design, the mean time between failures (MTBF) is 1.5 times that of the traditional UPS system; 4. More than 90% of the components in the system design adopt international brands, and the equipment has undergone 24-hour aging and related verification tests before leaving the factory to ensure the high reliability of the system. 30U
42U
Rectifier AC input (power supply)
battery
Inverter/inverter output (connect to critical load)
Bypass power input
|