model | SR6K/S | SR10K/S |
capacity* | 6000 VA / 4800 W | 10000 VA / 8000 W |
输入 |
voltage range | Minimum switching voltage | At 50% load, 110 VAC ± 3%; at 100% load, 176 VAC ± 3% |
Minimum recovery voltage | Minimum switching voltage + 10V |
Maximum switching voltage | 300 VAC ± 3 % |
Maximum recovery voltage | Maximum switching voltage-10V |
Frequency Range | 46Hz ~ 54 Hz @ 50Hz system 56Hz ~ 64 Hz @ 60Hz 系统 |
Phase | Single-phase grounding |
Power Factor | At 100% load ≧ 0.99 |
Output |
The output voltage | 208/220/230/240VAC |
AC voltage range | ± 1% |
Frequency range (synchronization range) | 46Hz ~ 54 Hz @ 50Hz system 56Hz ~ 64 Hz @ 60Hz system |
Frequency range (battery mode) | 50 Hz ± 0.1 Hz 或 60Hz ± 0.1 Hz |
overload | AC mode | 100%~110%: 3 minutes; 110%~130%: 30 seconds; >130%: 10 seconds |
Battery mode | 100%~110%: 3 minutes; 110%~130%: 30 seconds; >130%: 10 seconds |
Current peak ratio | 3:1 (maximum) |
Harmonic distortion | ≦ 3 % (Linear load) ≦ 5 % (non-linear load) |
Switching time | Mains ←→Battery | 0 ms |
nverter←→Bypass | 0 ms |
effectiveness |
AC mode | > 92% | > 93% |
Battery mode | > 90% | > 91% |
battery |
Standard machine | model | 12 V / 7 Ah 或 12 V / 9 Ah |
number | 16 | 20 | 16 | 20 |
Charging time | 90% capacity in 9 hours |
recharging current | Preset: 1 A ± 10%; Maximum: 1A or 2A optional |
Charging voltage | 218.4V ± 1% | 273V ± 1% | 218.4V ± 1% | 273V ± 1% |
Long extension machine | model | Varies according to usage |
number | 16-20 |
recharging current | Preset: 4 A ± 10%; Maximum: 1A, 2A, 4A or 6A optional (6A only applies to 16 batteries) |
Charging voltage | 218.4 V ± 1% (based on 16 batteries) |
Exterior |
Standard machine | Dimensions, depth x width x height (mm) | UPS host: 530 x 438 x 88 [2U] Battery box:668 x 438 x 88 [2U] | UPS host: 530 x 438 x 88 [2U] Battery box: 580 x 438 x 133 [3U] | UPS host: 580 x 438 x 133 [3U] Battery box:580 x 438 x 133 [3U] | UPS host: 580 x 438 x 133 [3U] Battery box:580 x 438 x 133 [3U] |
Net weight (kgs) | UPS host: 13 Battery box: 46 or 55 | UPS host: 13 Battery box: 53 or 64 | UPS host: 17 Battery box: 45 or 54 | UPS host: 17 Battery box: 53 or 64 |
Long extension machine | Dimensions, depth x width x height (mm) | 530 x 438 x 88 [2U] | 580 x 438 x 133 [3U] |
Net weight (kgs) | 13 | 17 |
Environmental conditions |
Operating temperature | 0 ~ 50°C (Battery life will be shortened in an environment> 25°C) | 0 ~40°C (Battery life will be shortened in an environment> 25°C) |
Operating humidity | <95 % without condensation |
Operating altitude** | <1000m** |
noise | Less than 55dB @ 1 Meter | Less than 58dB @ 1 Meter |
management |
Smart RS-232 or USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC |